LOW VOLTAGE SWITCHGEAR : MAINTENANCE, TESTING & TROUBLESHOOTING

Training Low Voltage Switchgear : Maintenance, Testing and Troubleshooting adalah program Training Engineering dari PT Gama Semesta Konsultindo. Training Low Voltage Switchgear : Maintenance, Testing and Troubleshooting diselenggarakan di Yogyakarta, Jakarta, Surabaya, Bandung, Semarang dan Bali.

 

Deskripsi Pelatihan / Training Low Voltage Switchgear : Maintenance, Testing and Troubleshooting

Switchgears (& circuit breakers) merupakan komponen penting dalam sistem distribusi listrik dan pengoperasiannya secara signifikan mempengaruhi operasi keseluruhan sistem. Pengoperasian medium voltage switchgear, dan testing adalah masalah yang berkaitan dengan listrik, dan voltage circuit breakers type high, medium, dan juga akan ada cakupan switchgear tegangan rendah (low voltage switchgear).

Pelatihan ini akan memberikan landasan menyeluruh dalam teori switchgear dan standard-nya. Peserta akan mendapatkan pemahaman mengenai aplikasi yang tepat, instalasi dan maintenance terhadap peralatan penting ini dengan penekanan utama pada aspek safety. Pelatihan akan bersifat komprehensif dan praktis, yang menekankan switchgear tegangan menengah (medium voltage switchgear) yang mewakili sebagian besar switchgear diinstal pada sistem distribusi listrik. Komponen sistem proteksi daya lainnya akan dibahas juga untuk memastikan bahwa switchgear dipahami dalam konteks yang benar.

 

Tujuan Pelatihan / Training Low Voltage Switchgear : Maintenance, Testing and Troubleshooting

  1. Dapat melakukan pemilihan jenis yang tepat dan rating dari circuit breakers dan switchgear
  2. Memahami dasar-dasar pengoperasian switchgear
  3. Mengetahui tentang komponen Switchgear (CTs, VTs, relay, terminasi kabel)
  4. Mengetahui kebijakan safety operasional, termasuk peraturan keselamatan dan keamanan dokumen
  5. Memahami pengoperasian switchgear
  6. Mampu melakukan pemeliharaan/maintenance dan testing pada switchgear.

Materi Pelatihan / Training Low Voltage Switchgear : Maintenance, Testing and Troubleshooting

  1. Switchgear – Origins and Types
  2. Application of switchgear
  • Principles of current interruption
  • Plain break circuit breakers
  • Bulk and small oil volume circuit breakers
  • Turbulator (explosion pot)
  • Operating mechanisms
  • Transfer earth circuit breakers
  • Air break and air blast switchgear
  • SF6 and Vacuum
  • Switchgear in association with disconnectors
  • Fixed and withdrawable designs
  • Switchgear standards
  • Factors affecting switchgear selection

    3. Specification of Switchgear

  • Switchgear rating – highest system and impulse withstand voltages, load and short circuit currents
  • Simple and complex protection systems
  • Switchgear ancillaries, measurement CTs, VTs, relays
  • Cable terminations
  • Indoor and outdoor operation
  • Substation and switch room layouts and design

    4. Short Circuit Testing

  • Symmetrical and asymmetrical breaking
  • Make and break operations
  • Understanding test oscillograms

    5. Safety Policies

  • General safety precautions and the use of personal protective equipment
  • Principles of safety rules
  • Principles of personnel authorization
  • Operative training for safe operation of switchgear
  • Isolation in a circuit breaker context
  • Safety documentation
  • Operational and safety locking, caution and danger notices
  • Safe working in a substation environment
  • Safety interlocks
  • Substation alarms
  • Individual study task and presentation -safety policies in my company and how they might be improved

    6. Operation of Modern Switchgear
    7. Asset Management in A Switchgear Content

  • Principles of time and condition based asset management
  • Asset registers
  • Asset management systems

    8. Diagnostics , Testing and Maintenance

  • Switchgear inspection methodologies
  • Partial discharge measurement and survey
  • Timing tests
  • Thermovision
  • Mechanisms of deterioration
  • Principles of circuit breaker maintenance
  • Maintaining oil circuit breakers
  • Contact maintenance and contact wipe
  • Oil testing
  • Maintaining vacuum circuit breakers
  • Maintaining SF6 circuit breakers
  • SOPs and DINs

Peserta Pelatihan / Training Low Voltage Switchgear : Maintenance, Testing and Troubleshooting

Peserta pelatihan adalah para personel yang bertanggung jawab dalam proses maintenance, testing dan troubleshooting low voltage power circuit breakers, protective relays, breaker trip devices dan switchgear panels.

 

Instruktur Pelatihan / Training Low Voltage Switchgear : Maintenance, Testing and Troubleshooting

Dr. Ir. Joko Waluyo, M.T dan tim

 

Waktu dan Tempat Pelatihan / Training Low Voltage Switchgear : Maintenance, Testing and Troubleshooting

  • 3 (hari) kerja, di Hotel berbintang Yogyakarta, Jakarta, Surabaya, Bandung, Semarang dan Bali
  • Available untuk kelas kecil dan kelas besar
  • Metode pelatihan dapat diselenggarakan secara online maupun offline
  • Fasilitas : Modul, sertifikat, training kit, souvenir, lunch, 2x coffee break

 

Jadwal Pelatihan / Training Low Voltage Switchgear : Maintenance, Testing and Troubleshooting fleksible dan dapat menyesuaikan permintaan (selama memenuhi kuota peserta).

 

Informasi lengkap tentang Pelatihan / Training Low Voltage Switchgear : Maintenance, Testing and Troubleshooting hubungi ibu Risma atau ibu Kusnuroini  di 0877-3989-1000, 0813-3532-3939, 0812-1516-0011, 0813-9229-0011 .

Leave a Reply

Your email address will not be published. Required fields are marked *

This site uses Akismet to reduce spam. Learn how your comment data is processed.